http:\/\/www.w3.org\/2001\/04\/xmlenc#sha256<\/a>” \/>
\n<\/bean><\/td>\n<\/tr>\n\n<\/td>\n<\/tr>\n |
\nReporting: ETL<\/td>\n | In rare cases, when a customer uses Oracle Database 11g and runs multiple DB instances for ephesoft, report and report_archive on the same database server, there might be an issue with fresh Transact 2019.1 installation. Since existing schema already has the “gt_batch_identifier” temporary table in the database, the same table will not be created during new installation and the clean-up job will fail and never complete its execution.<\/td>\n | The following queries need to be executed in the report database to fix the issue:<\/p>\n CREATE GLOBAL TEMPORARY TABLE gt_batch_identifier (identifier VARCHAR2(255)) ON COMMIT PRESERVE ROWS; \nCREATE INDEX ix_gt_bi_identifier ON gt_batch_identifier (identifier);<\/td>\n<\/tr>\n |
\n<\/td>\n<\/tr>\n |
\nFolder Import: IMPORT_MULTIPAGE_ \nFILES plugin<\/td>\n | Batch files size increases after classification when using Recostar for converting PDF to TIFF.<\/td>\n | Image size can be reduced by more than 50% if Ghostscript is used as PDF to TIFF conversion engine instead of Recostar in the IMPORT_MULTIPAGE_FILES plugin.<\/td>\n<\/tr>\n |
\n<\/td>\n<\/tr>\n |
\nFolder Import<\/td>\n | HTML and TXT files are not getting processed on Linux RHEL\/CentOS as conversion tool wkhtmltopdf is not working in Ephesoft Transact v.2019.1 (while no issues are observed in Linux Ubuntu environment).<\/td>\n | When processing HTML files, ITEXT conversion tool can be used as an alternate for wkhtmltopdf. For TXT files, the system will continue using LibreOffice. \nAll conversion tools are configurable in the dcma-import-folder.properties file (Ephesoft Installation Directory\\Application\\WEB-INF\\classes\\META-INF\\dcma-import-folder):# HTML files process through below softwares. Set value of import.import.html_conversion_tool corresponding to software \n# soffice – 1 \n# itext – 2 \n# wkhtmltopdf – 3 \nimport.html_conversion_tool=2<\/td>\n<\/tr>\n |
\n<\/td>\n<\/tr>\n |
\nMulti-cluster Environment<\/td>\n | Batches created from NODE2 and NODE3 in a multi-node cluster with three nodes (e.g. NODE1, NODE2, NODE3) are not getting processed and are not displayed on the Batch Instance Management screen.<\/td>\n | To fix the issue, follow the steps mentioned below for each node of the cluster:<\/p>\n 1) Go to Ephesoft Installation Directory\\Application\\WEB-INF\\classes\\META-INF\\dcma-folder-monitor \n2) Open the folder-monitor.properties file in a text editor \n3) Set the foldermonitor.jnotify_switch to false \nfoldermonitor.jnotify_switch=false \n4) Restart Ephesoft Transact.<\/td>\n<\/tr>\n |
\n<\/td>\n<\/tr>\n |
\nSSO: Infor Installer<\/td>\n | When running any phase installer for Infor, the SSO beans are being commented in the applicationContext.xml.<\/td>\n | To fix the issue, after running the Infor installer, the SSO bean in the applicationContext.xml property file (Ephesoft Installation Directory\\Application) needs to be manually modified and enabled as shown below:<\/p>\n <!– Uncomment to Use SAML SSO –> \n<import resource=”classpath:\/META-INF\/applicationContext-security.xml” \/><\/td>\n<\/tr>\n |
\n<\/td>\n<\/tr>\n |
\nBatch Instance Management Screen<\/td>\n | The user is unable to change the batch instance priority from the Batch Instance Management page. The field turns red when the user attempts to edit it.<\/td>\n | To resolve this issue, directly update the batch_priority<\/strong> column in the batch_instance<\/strong> table in the Ephesoft database for the applicable batch instance.<\/p>\n Note: <\/strong>This issue is fixed in Ephesoft Transact 2019.2.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":0,"parent":28466,"menu_order":5,"comment_status":"closed","ping_status":"closed","template":"","doc_tag":[],"yoast_head":"\nEphesoft Transact 2019.1 Known Issues & Workarounds | Ephesoft Docs<\/title>\n\n\n\n\n\n\n\n\n\n\n\n\t\n |